Applications:
- Laboratory technology
- General machine building
Special features:
- USB interface for measured-value display on the PC
- Non-contact sensor (wear-free)
- Nominal size 50
- Scale ranges 0 … 1,6 bar to 0 … 400 bar
Description:
- Design EN 837-1
- Nominal size in mm 50
- Accuracy class 2.5
- Scale ranges 0 … 1.6 to 0 … 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation:
- Steady: 3/4 x full scale value
- Fluctuating: 2/3 x full scale value
- Short time: Full scale value
Permissible temperature:
- Ambient: -20 … +60 °C
- Medium: +60 °C maximum
Temperature effect: When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
Process connection:
- Copper alloy, lower mount (LM)
- G 1/4 B (male), 14 mm flats
Pressure element:
- Copper alloy, C-type
- Movement Copper alloy
- Dial Plastic, white, black lettering
- Pointer Plastic, black